RAID |
|
Multiple arrays configurable with dedicated or
global hot spares |
|
RAID levels supported: RAID 0, 1 (0+1), 3, 5, 10,
30, 50, NRAID and JBOD
|
|
Online expansion by:
|
|
- Adding new drives
- Copying and replacing drives with drives of
larger capacity
|
|
Automatic background rebuilds
|
|
Configurable stripe size and write policy per
array |
|
Intelligent drive handling:
|
|
- In degraded mode: skips irreparable blocks to
continue rebuild
- In normal operation: data-block verification
and repair
|
|
Host
Interface |
|
- Two (2) SCSI-320 through four (4) VHDCI 68-pin
SCSI ports; SCSI-160 backward compatible
- Concurrent I/O commands
- Tagged command queuing up to 256
- Variable stripe size per logical drive
- Optimization setting for random or sequential
I/Os
|
|
Drive
Interface |
|
- Twelve (12) or eight (8) 3Gbps SATA-II,
hot-swappable drive trays that accommodate
1-inch pitch, 3.5-inch SATA-I or SATA-II disk
drives
- Automatic bad-sector reassignment
- Dedicated bandwidth to each connected drive
|
|
System
Components |
|
Single controller configuration provides full RAID
functionalities |
|
- One (1) EonStor® enhanced 2U enclosure
- One (1) RAID controller module
- One (1) 256MB DDR RAM DIMM module
(pre-installed on the controller module)
- Two (2), hot-swappable, redundant, 350W power
supply units
- Three (A12U) or Two (A08U), hot-swappable,
redundant, single-fan cooling modules running in
high/low speeds
- Twelve (12) or eight (8), hot-swappable drive
trays
- Two (2) front handles
- Optional battery backup unit (BBU)
|
|
Management |
|
Front LCD control panel for setup and
configuration
|
|
10/100 BaseT Ethernet for out-of-band management |
|
One (1) RS-232C serial port for local access to
firmware-embedded utility |
|
Firmware-embedded Java-based RAIDWatch® GUI
manager:
|
|
- VT-100 terminal emulation via RS-232C
- Telnet access via onboard Ethernet port
- Cross-platform, remote administration with SSL
- Out-of-band access via Ethernet
- Centralized management to monitor and
administer multiple RAID units on one screen
|
|
Configuration client for real-time event
notification over Email, Fax, LAN broadcast, SNMP
Traps, MSN messenger, ICQ, SMS short messages, and
the configuration utility screen
|
|
SNMP agent support:
|
- SNMP trap event notification with plain-text
event message (no MIB file required)
- SNMP V2.0 MIB file support with get-and-set
commands
|
|
Indicators |
|
Onboard alarm is triggered when one of the
following modules fails: |
- RAID controller module
- Cooling module
- Power supply unit
- Hard drive
- BBU module
|
Module status LED indicators: |
- Two (2) per drive tray
- Two (2) per cooling module
- One (1) per power supply unit
- One (1) per BBU module
- Three (3) per LCD panel
- Five (5) per RAID controller module
- Two (2) per Ethernet port
|
Module failure alert through I2C bus |
|
Intelligent
Drive Handling |
|
If two bad blocks occur on two member drives of an
array, the integrity of the stored data is
endangered. Media Scan, Infortrend’s innovative
intelligent drive handling function, retrieves data
from the damaged sectors. Media Scan handles low
quality drives in both the degraded mode and during
the rebuild process. For additional data security,
other intelligent drive management features include
the transparent resetting of hung hard drives,
power-failure management, and bad-drive handling
during LD expansion. |
|
Task
Scheduler |
|
The Task Scheduler is combined with Media Scan so
that the scanning operation can be scheduled
beginning at a specified start time and repeating at
the configurable intervals. The operation is thus
hands free. Each such schedule can be defined to
operate on individual hard drives, all drives of a
certain class, all member drives of a specified
logical drive, or all member drives of all logical
drives. |
|
Interfaces |
|
- Four (4) ports in two (2) dual-stacked VHDCI
SCSI connectors
- One (1) COM port (38400, n, 8, 1)
- One (1) 10/100BaseT Ethernet port
|
|
Power
Supply Module |
|
Two (2) redundant hot-swappable power supplies
with PFC |
|
Input: |
100VAC at 10A,
240VAC at 5A with PFC (auto-switching) |
47 ~ 63Hz |
Output: |
(Maximum output: 350 Watts) |
|
+12.0V |
25A max. |
|
+ 5.0V |
25A max. |
|
+ 3.3V |
20A max. |
|
|
Cooling
Module |
|
Three (A12U) or two (A08U) redundant single-fan
cooling modules |
|
Maximum air flow (each module)
: |
High speed: 31.8 CFM
Low speed: 20.1 CFM |
|
|
Environmental
Specifications |
|
Operating temperature: |
0° to 40°C |
Non-operating temperature: |
-40° to 60°C |
Relative humidity: |
5 ~ 95%, non-condensing |
Operating altitude: |
Operating: 0 ~ 12,000 ft
Non-operating: 0 to 20,000 ft |
|
|
Dimensions |
|
- Chassis without handles: 446(W) x 88(H) x
490(D) mm
- Chassis with handles: 482 (W) x 88(H) x 505(D)
mm
- Package: 381H x567W x 772D mm
|
|
System
Weight |
|
- Net weight: 23.5kg
- Gross weight: 25kg
|